Service door – GE Industrial Solutions NEMA EVSE CHARGING STATION User Manual

Page 44

Advertising
background image

g

EV Charging Station

User Manual & Installation Instructions

GE EV Charging Station User Manual

44 of 86

After the old holding socket is removed, insert the replacement holding socket and tighten the
placement screws.

Re-connect the holding socket wire to the Phoenix connector, and re-connect the Phoenix connector
to the controller.

2.9.4 Service Door







Remove the service door.

Remove the door ground wire from door ground stud, shown in Figure 49.




Insert the new door and replace the ground wire to the door ground stud.

Figure 49: Door Ground Connection

WARNING: Make sure power to the EVSE is