MENU START

Function Signals

the

beginning of a menu definition and

specifies the menu storage location and identifier.

NOTE: This command does not execute the menu;
the command only prepares the printer to receive the
menu for storage. Use

Recall Menu

to execute

stored menus.

Explicit Form

MENU START x menuname

Implicit Form

MU START x menuname

Parameters

x

Storage location. You can store

menus in the following memory
areas:

x

Location

0

Volatile RAM

1

Reserved

2

Expanded Memory

3

Nonvolatile RAM

menuname

The menu identifier can be up to

eight alphanumeric characters. The

first character must be an
uppercase or lowercase letter (A-Z

or a-z).
The menu name __BOOT__ (the

word BOOT preceded and followed
by two underscore characters) is

reserved for an autostart routine.

Use this menu name only if you
want the printer to execute the

menu automatically on power-up.
The printer will always try to

execute __BOOT__ when it is