P R I N T E R S E T U P

VARIABLE ON_TIME

Function OBSOLETE

Explicit Form

Implicit Form

VARIABLE ON_TIME time

V ON_TIME time

VARIABLE OVERRIDE

Function

Enables or disables printing at slower speeds when

rotated barcodes are detected in the label format.

Explicit Form

VARIABLE OVERRIDE status

Parameters

status

The speed at which to print labels
containing rotated barcodes, in

thousandths of an inch. Allowable

values are 2000 to 5000, with a default
of 2000.
ON will enable this feature.
OFF will disable this feature.
A ? returns the current setting status.

Comments

When using this command, send it to the printer
with VARIABLE WRITE in a non-printing label

format. Do not use this command in stored label
formats.

Example

! 0 0 0 0

VARIABLE OVERRIDE 2000

VARIABLE WRITE

END