VARIABLE MEASURE_LABEL

Function

Enables or disables automatic label length

measurement when performing an index
calibration.

Explicit Form

Implicit Form

VARIABLE MEASURE_LABEL status

V MEASURE LABEL status

Parameters

status

ON – Labels will be measured during
index calibration.
OFF – Labels will not be measured

during index calibration.
? – Returns the current setting status.

Comments

This command is used to enable or disable
automatic label measuring when an index

calibration is performed.

When using this command, send it to the printer

with VARIABLE WRITE in a non-printing label

format. Do not use this command in stored label
formats.

See also

VARIABLE LABEL_LENGTH

,

VARIABLE

GAP_SIZE

Example

The format below will enable label measurement
during index calibration:

! 0 0 0 0

VARIABLE MEASURE_LABEL ON

VARIABLE WRITE

END