T R O U B L E S H O O T I N G

Common Issues

This section describes printing issues that you may encounter and

suggestions for resolving them.

Printer does not respond to incoming data.

Cause: The label format does not terminate with a proper END
command.

• Cure: Terminate all label formats with an END command,

unless specifically instructed otherwise by a particular command
description. Terminate every format line with a carriage return and

line feed.

Cause: The host system is not sending pure ASCII data.

• Cure: Check your system documentation to confirm that the
host is sending ASCII data. Some software uses formatting that is

incompatible with ASCII driven devices.

Cause: The label format contains an incompatible command. Some

commands will only work with certain printers.

• Cure: Rewrite the label format as required, removing

incompatible commands.

Cause: The label format contains extraneous control characters,

such as "@" or "#."

• Cure: Be careful when using reserved characters in label

formats. You can print the @ sign and other reserved characters,

but if you use such characters at the beginning of a line the printer
may "hang."

Cause: If you are sending data to a 4.25" portable printer it may be
asleep.

• Cure: Precede every label format sent to a 4.25" portable with
the proper wake-up string.