P R I N T E R S E T U P

The sensitivity of this mode

is adjustable with the
CALIBRATE

mode.

CALIBRATE

Runs an index calibration,
and then replaces the index

data currently stored for
mode 3 with the new data.

The C Series printer uses

only this parameter, not any
of the other parameters.

NOTE: Confirm that the
correct print media is loaded
before starting the calibration.

Comments

When using the VARIABLE INDEX SETTING modes

0, 1, or 2, send the command to the printer with
VARIABLE WRITE

in a non-printing label format.

The use of VARIABLE WRITE is optional when using

the VARIABLE INDEX SETTING CALIBRATE
command. VARIABLE INDEX SETTING CALIBRATE

always writes its data to nonvolatile RAM, with or
without the use of VARIABLE WRITE.

Do not use this command in stored label formats.

The CALIBRATE mode runs an automatic calibration

routine that measures the opacity of the currently

loaded ribbon, labels, and backing, then uses these
values to set the index detector sensitivity. This

takes about 15 seconds in most printers. The
printer's READY light flashes during calibration.

The ready light will glow green if the calibration is
successful and red if the calibration is unsuccessful.

Following a successful calibration, the printer

automatically writes the new index calibration to
nonvolatile RAM.

Revision F, January 2012, CognitiveTPG

209