Gate Bracket and Chain Installation

1-14

SlideSmart Installation and Reference Manual

Revision D

8. To verify that the operator recognizes the target magnet, turn off both DC and AC power switches and

watch the display go blank. Then, turn both switches on. The operator beeps indicating Limit Relearn
Mode. The gate then travels about 6 inches (15cm) in the open direction and stops. The buzzer beeps
again and the gate travels in the close direction at a rate of ½ ft/s until the target magnet passes the target
sensor. The buzzer sounds one last time, the operator resets, and “GATE CLOSED” appears on the
display.

9. If “LEARN OPEN” appears, then the target magnet was not detected. Check chain alignment and make

sure the target magnet passes across the face of the sensor. See Figure 1-18. Repeat steps 6 - 8. If you are
still having difficulty with the operator learning its limits, re-install the target magnet. See

Establishing

the OPEN & CLOSE Limits

on page 1-12.

F

RONT

I

NSTALLATION

Figure 1-19.

CAUTION

When the gate is CLOSED, the target magnet should stop between the idler wheel and
the roller chain sprocket. The target magnet MUST NOT enter the sprocket teeth. See
Figure 1-19.

PUBLIC

PUBLIC

SECURE

SECURE

Roller chain sprocket

Idler wheel

Target

(LH gate)

sensor

Position of the target
magnet when the gate is
fully closed.

Second target
sensor is not used

Trailing edge of gate

(Gate shown in full
CLOSE position)

Advertising