Enabling the fire department override -21, Enabling the fire department override – Controlled Products Systems Group SLIDESMART DC 10F User Manual

Page 73

Advertising
background image

Installer Menu

Revision D

Display and Menu Options

3-21

Enabling the Fire Department Override

Many counties and cities require a Fire Department override system for gate operators. The fire department’s
alert system is a separate unit that must be connected to the Smart DC Controller. The FIRE DEPARTMENT
OPEN option must be properly configured through the Installer Menu before the operator will recognize the
alert system.
To enable the Fire Department Override, take the following steps:
1. Connect the contact NO from the alert system or key switch to the following Smart DC Controller

terminals:
EMERG OPEN
+24V

2. Configure the Installer Menu.

At a gate status display, press the MENU button
twice. This accesses the User Menu and the
CLOSE TIMER display appears.

3. Simultaneously, press the OPEN and RESET

buttons to enter the Installer Menu.
Release the buttons and the USAGE CLASS
display appears. It is the first item in the Installer
Menu.

4. Press NEXT until the FIRE DEPARTMENT

OPEN display appears. The factory default
setting is 0.

5. Use the NEXT button to change the number on

the display to 1 and then press SELECT.

6. To exit the Installer Menu, press the MENU

button. The gate status appears in the display
indicating you have returned to Run Mode.

HYSECURITY

GATE CLOSED

OPEN

CLOSE

STOP

MENU

RESET

PREV

NEXT

SELECT

CT 0 (OFF)

CLOSE TIMER

OPEN

CLOSE

STOP

MENU

RESET

PREV

NEXT

SELECT

FO 1

FIRE DEPT OPEN

OPEN

CLOSE

STOP

MENU

RESET

PREV

NEXT

SELECT

1. Start at a gate status
display.

2. To access the User
Menu, press MENU
twice.

3. To access the
Installer Menu,
simultaneously, press
OPEN and RESET

4. Use NEXT to
navigate to the menu
display. Change the
setting using the
SELECT and NEXT
buttons.

LL 0 (OFF)

LEARN LIMIT

OPEN

CLOSE

STOP

MENU

RESET

PREV

NEXT

SELECT

COM

STOP

OPEN

RADIO

CLOSE

OPEN

OPEN

PARTIAL

EYE

OPEN

EYE

CLOSE

EXIT

LOOP
BLOCK

EXIT

IN OBS

LOOP

OUT OBS

LOOP
CENTER

LOOP
EDGE
EYE

COM
+ 24 V
EMERG
OPEN

SHOW

LEDs

FIRE

Advertising
This manual is related to the following products: