3-8

SlideSmart DC Installation and Reference Manual

Revision D

Adjusting the Close Timer

The close timer assigns how many seconds will pass before the operator initiates closure of a fully opened gate
after all open commands and reversing sensor inputs have ceased. Every gate operator needs to have the close
timer set to a specific number of seconds unless a hard-wired closing device is connected to the unit such as a
push button station.

To adjust the time (1 to 99 seconds) it takes before the operator initiates gate closure, take the following steps:

1. At a gate status display, press the MENU button

twice. This accesses the User Menu and the CLOSE
TIMER display appears.

2. Use the SELECT, and then NEXT or PREV buttons

to navigate and change the number on the display.

Note:Keep the close time at zero if gate personnel operate

the gate or the owner plans to use a remote control.

3. To exit the User Menu, press the MENU button.

The gate status appears in the display indicating you
have returned to Run Mode.

CT 0 (OFF)

CLOSE TIMER

OPEN

CLOSE

STOP

MENU

RESET

PREV

NEXT

SELECT