Overview of the Smart DC Controller

4-8

SlideSmart DC Installation and Reference Manual

Revision D

Figure 4-4. Standard 11-Pin Box Type Vehicle Detector

V

EHICLE

D

ETECTOR

C

ONFIGURATION

AND

Q

UICK

C

LOSE

M

ODE

S

ELECTION

The Standard Quick Close modes are selectable in the Installer Menu. Refer to

Table 3-2 on page 3-22

.

The four selectable modes are described as follows:

Mode 1 (Default)

An input from either the Free Exit, Outside Obstruction Loop, Inside Obstruction Loop or the Center
Loop will hold the gate open, reset the close timer, and block all close inputs.

Mode 2

Same function as Mode 1, except the close timer can count to zero even with the Free Exit, Outside
Obstruction Loop, Inside Obstruction Loop or the Center Loop detector inputs active. If the close timer
has counted to zero, the gate will close when all detector inputs are clear.

Mode 3

Same function as Mode 1. However, the close timer is forced to zero when both the OOLD & IOLD are
tripped simultaneously. Additionally, all other close inputs are memorized and the gate closes immediately
when all open commands and vehicle detector inputs are clear.

Mode 4

Full anti-tailgate logic includes Mode 3 functions. In addition, the gate will stop during the opening cycle
when both OOLD & IOLD are tripped simultaneously. When the OOLD & IOLD loops are cleared, the
gate closes immediately. The OOLD & IOLD can be individually set so that, if tripped while closing, the
gate may pause only or reverse to reopen. The free exit detector input is blocked while the gate is closing.

Inside

ObstrucƟon

Loop Detector

Outside

ObstrucƟon

Loop Detector

Free Exit

Loop Detector

Center

Loop Detector

PIN 1

PIN 2

Common

FREE EXIT LOOP terminal

IN OBS LOOP terminal

OUT OBS LOOP terminal

CENTER LOOP terminal

LOOP

LOOP

LOOP

LOOP

24VAC or 24VDC

Connect detector to match
its voltage rating

The center loop serves no
gate function but the detector
can be used as an arming loop
when used in conjunction
with User
Relay 22.