Controlled Products Systems Group SLIDESMART DC 10F User Manual

Page 94

Advertising
background image

Connecting Accessory Devices

4-12

SlideSmart DC Installation and Reference Manual

Revision D

13

Loitering Alert

Indicates a vehicle is loitering on the Outside Obstruction Loop. Adjustable from 0 delay to
135 seconds delay in 30-second time intervals.
Note: LT - LOITERING ALERT adjustments can be made in the Installer Menu.

14

Gate nearing full travel output

Activated when the gate is three feet from full travel in both the open and close directions.
This output is used to reduce the sensitivity of a proximity sensor near the ends of gate travel.

15

Gate Failure output

Activated to report occurrence of a problem. Indicates the system is in an Error Mode, Fault
Mode or Entrapment Mode. If active, the gate is disabled.

16

Motor Running output

Active when the motor is running and the gate is in motion.

17

AC Power Failure output

This relay is normally energized and drops with loss of AC power.

18

DC Power Failure output

Activated when the battery power is very low, but the output ceases when the battery is dead.
The relay is triggered when the battery is less than 20 Volts.

19

Flasher Relay

Controls flashing lights that pulse once per second. The relay is constantly activating except
when the open limit switch is triggered.

20

Free Exit Loop Vehicle Detector
output

Active whenever the Exit Loop is tripped.

21

Inside Obstruction Vehicle
Detector output

Activated when the Inside Obstruction Vehicle Detector is tripped.

22

Center Loop Detector output

Activated when the center loop detector is tripped. Since this input is not used for a sliding
gate, User Relay 22 can be used in combination with a detector to perform the function of an
arming loop detector because there is no associated gate control logic.

23

External Latching Gate Lock
Output

Not used in the Smart DC Controller

24

Gate at Partial Open Position

Active when the partial open position is reached or exceeded.

25

DC Power Alert

Deactivates when the software detects a low battery voltage (below 21VDC, but greater than
18VDC) for a duration of 2 seconds or more. To slow battery drain, accessory power loads are
shed. Connect wiring to Relay 2, and then program the Installer Menu item Relay 2 Logic by
entering the number 25 in its data field.

Table 4-3. User-Programmable User Relays - Function Options (Continued)

No.

Name

Description