Overview of the Smart DC Controller

Revision D

Smart DC Controller

4-3

All the control device inputs listed in Table 4-1 are shown as a single input. The second wire is connected to a
Common Terminal Bus (1 - 8) on the Smart DC Controller board.

The Fire Department Open input is an exception and requires a +24VDC input as well as activation through
the Installer Menu. For convenience a +24VDC terminal is located next to the EMERG OPEN terminal.
See Figure 4-2. Note that programming in the User or Installer Menu is required for most connections.

Table 4-1. Smart DC Controller Board Inputs

Terminal
No.

Input Name

Use

1- 8

Common Terminal

All user inputs are energized when connected to common except
Emergency Open.

9

Stop * push button

Normally Closed (N.C.). input. Jumper to Common if not being used.

10

Open * push Button

Normally Open (N.O.) input. Not for radio or remote access controls.

11

Close push button

N.O. input. Connection for a close push-button.

12

Remote Open and Radio Control**

N.O. input. For radio/remote open or close device - Access the User
Menu and program RO RADIO OPEN/CLOSE.

13

Partial Open

N.O. input. Connection to EYE OPEN and EYE COM. Program PO
PARTIAL OPEN in the Installer Menu to set the distance (from the
closed gate position) where the gate stops in a partial open position.

14

Photo Eye Open direction

N.O. input. Connection for Photo Eye Open direction. Can be changed
to a supervised Normally Closed (N.C.) contact through the Installer
Menu.

15

Photo Eye Close direction

N.O. input. Connection for Photo Eye Close direction. Can be changed
to a supervised Normally Closed (N.C.) contact through the Installer
Menu.

16

Free Exit Vehicle Detector

N.O. input. Connection for free exit vehicle detector.

17

Block Free Exit vehicle detector or Close
Timer

N.O. input. Free Exit is only disabled if Close Limit Switch is tripped. If
the gate is partially opened, the Free Exit detector will trigger the gate to
open fully. The input can be converted in the Installer Menu to
alternately disable the Close Timer.

18

Inside Obstruction Vehicle Detector

N.O. input. Inside reversing loop.

19

Outside Obstruction Vehicle Detector

N.O. input. Outside reversing loop.

20

Center Loop (Shadow) Vehicle Detector

N.O. input. Center loop function not used for slide gates.

21

Edge Sensor

N.O. input. One input works for both directions of travel. It can be
changed to N.C. contact through the Installer Menu.

22

Photo Eye Common

When the Photo Eye Open and Photo Eye Closed common wires are
connected to this terminal, the photo eyes energize only when the motor
runs. Use these terminals to preserve battery power.

23

+24V DC

Convenient 24VDC power for photo eyes or the Emergency Open
input.

24

Emergency Open (Fire Dept.Open) ***

N.O. input. The Emergency Open must be enabled via the Installer
Menu. It is energized by connecting to the +24V terminal above it. The
EMERG OPEN overrides photo eye & edge sensor commands.

*Do not connect an external control to the STOP or OPEN inputs unless the controls are located in clear view of the entire gate area.
**Use the RADIO OPEN input or RADIO OPTIONS spade connections for all out-of-sight controls, such as a telephone entry or
radio operated controls.
***The Fire Department Open control must be keyed or guarded so that it can only be used by authorized personnel.