Setting AC Power Loss Gate Function

The setting in the AC LOSS display determines what action the operator performs during an AC power loss.
The settings help reduce drain on the battery. You can choose between four settings depending on customer
preferences.

NOTE

DC Solar Powered units can only be set for AP0 or AP1.

Menu Setting

Description

Normal gate functions continue until the system detects a battery voltage drop below 21V.
DEAD BATTERY appears on the display and the gate automatically opens. Any push-
button CLOSE command will close the gate and any open command will re-open the gate.
If the battery continues to diminish and the system detects 18V or less, the system initiates
an automatic open cycle. Any new open or close command is ignored and the LCD appears
blank. The system remains in this disabled state until reset or the battery recovers to 24V.

Normal gate functions continue until the system detects a battery voltage drop below 21V.
DEAD BATTERY appears on the display and the gate automatically closes. The gate can be
opened by a special sequence of a STOP input followed by an OPEN push-button or directly
opened with the Fire Department Open command. Any push-button CLOSE command will
close the gate. If the battery continues to diminish and the system detects 18V or less, the
system initiates an automatic open cycle if not already on a limit. Any new open or close
command is ignored and the LCD appears blank. The system remains in this disabled state
until reset or the battery recovers to 24V.

The operator automatically opens the gate five seconds after it detects an AC power loss. The
gate remains open until AC power is restored. Any push-button CLOSE command will close
the gate and any open command will open the gate. When the battery voltage drops below
21V or less, the system initiates an automatic open cycle. The gate will remain open until
the battery recovers to 24V.

The operator initially does nothing after it detects AC power loss until it receives an open
command. Once an open command is received, the operator opens and remains in that state.
Any push-button CLOSE command will close the gate and any open command will open
the gate. When the battery voltage drops below 21V or less, the system initiates an automatic
open cycle. The gate will remain open until the battery recovers to 24V.

To designate what you want the operator to do during an
AC power loss, access the User Menu (see

User Menu

) and

scroll through the items until the AP (AC LOSS) display
appears:
1. Use the SELECT and NEXT buttons to navigate and

change the number on the display. Review

Using the

Smart DC Controller Buttons In Menu Mode

.

2. To exit the User Menu, press the MENU button. A

gate status appears in the display indicating you have
returned to Run Mode.

AP 0 AC LOSS

UPS FAIL OPEN

AP 1 AC LOSS

UPS FAIL CLOSE

AP 2 AC LOSS

AUTO OPEN

AP 3 AC LOSS

NO CLOSE TIMER