Reinstating Factory Defaults

Ten menu configurations are available in the User Menu. Several other items in the Installer Menu let you
customize the operator depending on the number of attached accessories and your customer’s needs.

CAUTION

Reinstating factory default clears ALL menu settings stored in the operator and returns them to fac-
tory defaults. It is recommended that you save the menu settings before reinstating
factory defaults. You can write the settings in a notebook or, if you have a laptop computer, you can
use HySecurity’s START software and download the menu settings and save them to a file to upload
to the operator at a later date.

To reinstate factory defaults, take the following steps:

1. At a gate status display, press the MENU button

twice. This accesses the User Menu and the
CLOSE TIMER display appears.

2. Simultaneously, press the OPEN and RESET

buttons to enter the Installer Menu.
Release the buttons and the LEARN LIMITS
display appears. It is the first item in the Installer
Menu.

3. Press NEXT until the FACTORY DEFAULTS

display appears. The factory default setting is 0.

4. Use the SELECT and NEXT buttons to

navigate and change the number on the display
to 1.

Note:When you press SELECT to accept FD 1, the

factory settings are reinstated immediately
and the menu display returns to the initial
Setup Menu. The gate operator will not run
until the three menu parameters are entered:
Usage Class, Gate Handing, and Gate
Weight. The limits will also need to be re-
learned. Refer to

Programming the Initial

Setup Menu

and

Establishing the OPEN &

CLOSE Limits

.

HYSECURITY

GATE CLOSED

OPEN

CLOSE

STOP

MENU

RESET

PREV

NEXT

SELECT

CT 0 (OFF)

CLOSE TIMER

OPEN

CLOSE

STOP

MENU

RESET

PREV

NEXT

SELECT

FD 1 (ON)

FACTORY DEFAULTS

OPEN

CLOSE

STOP

MENU

RESET

PREV

NEXT

SELECT

1. Start at a gate status
display.

2. To access the User
Menu, press MENU
twice.

3. To access the
Installer Menu,
simultaneously, press
OPEN and RESET

4. Use NEXT to
navigate to the menu
display. Change the
setting using the
SELECT and NEXT
buttons.

LL 0 (OFF)

LEARN LIMIT

OPEN

CLOSE

STOP

MENU

RESET

PREV

NEXT

SELECT