Important Considerations for DC-powered Operators

Revision D

Power

2-13

4. Place the two 50Ah batteries on

the tray.

5. Attach the blue wire from the

red terminal on one 50Ah
battery to the black terminal on
other 50Ah battery.

6. Run the red and black wires

(disconnected from the 8Ah
batteries) through the hole in
the support bracket.

7. Using the wires supplied in the

50Ah battery kit, attach the red
wire to the red positive terminal
on the 50Ah battery. Connect
its opposite end to the red lead
exiting the support bracket.

8. Connect the black wire to the

black negative terminal on the
50Ah battery. Connect its
opposite end to the black lead
exiting the support bracket.

9. Access the Installer Menu on the

Smart DC Controller.

10. Change the Battery Setting (BT)

in the Installer Menu to a
number 1 (Extended). Follow
the steps in the menu tree
shown here.

Black

Blue

Red

Figure 2-10.

50Ah batteries

Accessory tray

Post-mounted
operator with
base extension

BT 1 (EXTENDED)

BATTERY TYPE

OPEN

CLOSE

STOP

MENU

RESET

PREV

NEXT

SELECT

HYSECURITY

GATE CLOSED

OPEN

CLOSE

STOP

MENU

RESET

PREV

NEXT

SELECT

CT 0 (OFF)

CLOSE TIMER

OPEN

CLOSE

STOP

MENU

RESET

PREV

NEXT

SELECT

1. Start at a gate status display.

2. Access the User Menu, by
pressing MENU twice.

3. Access the Installer Menu, by
simultaneously pressing OPEN
and RESET. Release the buttons.

4. Use NEXT to navigate to the
menu display. Change the setting
using the SELECT and NEXT
buttons.

LL 0 (OFF)

LEARN LIMIT

OPEN

CLOSE

STOP

MENU

RESET

PREV

NEXT

SELECT

Advertising