Resetting the open and close limits -16, Resetting the open and close limits – Controlled Products Systems Group SLIDESMART DC 10F User Manual

Page 68

Advertising
background image

Installer Menu

3-16

SlideSmart DC Installation and Reference Manual

Revision D

Resetting the OPEN and CLOSE Limits

On occasion, the open and close limits may need to be fine-tuned. Resetting the open and close limits is easily
accomplished by accessing the Installer Menu. Examples where resetting the limits is necessary

,

include:

Replacing the chain or adjusting the chain to the point where it affects the open and close positions

Removing or replacing the target magnet

Setting the LEARN LIMITS display to 1 (erases the open and close target positions from memory)

To re-learn limits, take the following steps:

1. At a gate status display, press the MENU button

twice. The CLOSE TIMER display appears.

2. Simultaneously, press the OPEN and RESET

buttons to enter the Installer Menu.
Release the buttons and the LEARN LIMITS
display appears. It is the first item in the Installer
Menu.

3. Press SELECT, and then NEXT to change the

setting to 1. Press SELECT again.
LEARN OPEN flashes on the display indicating
that operator is ready to relearn the open limit.

4. Hold the OPEN button until the gate reaches

the desired open limit. Release the OPEN
button. (Note that if you go too far, you can
press CLOSE to reverse direction.)

5. Press STOP twice to preserve the open stop

location.
LEARN CLOSE appears on the display.

6. Hold the CLOSE button until the gate slides to

full close. Release the CLOSE button (Note that
if you go too far, you can press OPEN to reverse
direction.)

7. Press STOP twice. The full close stop is retained

in memory. For more information, refer to

Establishing the OPEN & CLOSE Limits

.

Note:Do not set limits at the physical OPEN and

CLOSE stops. Leave a 1 to 2-inch (2.5 -
5cm) gap to allow for minimal drift.

8. An ALERT 15 message appears on the display.

To clear the alert, perform a full cycle so the
software recognizes the target. Press OPEN, and
then CLOSE. The gate will stop automatically
on the close cycle when it reaches the programmed limit. As the target magnet passes the sensor, the
operator beeps and the ALERT 15 message is cleared.

HYSECURITY

GATE CLOSED

OPEN

CLOSE

STOP

MENU

RESET

PREV

NEXT

SELECT

CT 0 (OFF)

CLOSE TIMER

OPEN

CLOSE

STOP

MENU

RESET

PREV

NEXT

SELECT

LL 0 (OFF)

LEARN LIMIT

OPEN

CLOSE

STOP

MENU

RESET

PREV

NEXT

SELECT

1. Start at a gate status
display.

2. Access the User
Menu by pressing the
MENU button twice.

3. Access the Installer
Menu, by simul-
taneously, pressing the
OPEN and RESET
buttons.

4. Press SELECT and
change the setting to
1 using the NEXT
button. Press
SELECT again. The
LEARN OPEN
display appears. refer
to steps 4 through 8.
For more

LL 1 (ON)

LEARN LIMIT

OPEN

CLOSE

STOP

MENU

RESET

PREV

NEXT

SELECT

Advertising
This manual is related to the following products: