Master and Slave Wiring Connections

5-2

SlideSmart DC Installation and Reference Manual

Revision D

M

ASTER

AND

S

LAVE

W

IRING

C

ONNECTIONS

Figure 5-2.

1. As shown in Figure 5-2, connect a shielded communications cable to the DUAL GATE inputs in each

unit. The inputs are located near the base of the Smart DC Controller. Be sure to connect the wires in pairs
to the same terminal ports (A-A, B-B, and COM to COM) on both units. See Table 5-1.

2. Attach a ring terminal to the shield wire and connect it to the Smart DC Controller’s convenient ground

screw. Refer to Figure 5-2.

NOTE

Connect the ground shield wire to only one operator, not both.

Table 5-1.

Slave

Master

A

A

COM

COM

B

B

Shield wire to Ground*

* Only ground to one
unit. Do NOT attach the
shield wire to both units.

COM

EXIT

LOOP
BLOCK

EXIT

IN OBS

LOOP

OUT OBS

LOOP
CENTER

LOOP
EDGE
EYE

COM
+ 24 V
EMERG

OPEN

SHOW

LEDs

RADIO OPTIONS

EDGE +24V OP

EN COM

DUAL GATE

B

A

U

SE

R2

COM NO

DC

USER 1

COM

EXIT

LOOP
BLOCK

EXIT

IN OBS

LOOP

OUT OBS

LOOP
CENTER

LOOP
EDGE
EYE

COM
+ 24 V
EMERG

OPEN

SHOW

LEDs

RADIO OPTIONS

EDGE +24V OP

EN COM

DUAL GATE

B

A

U

SE

R2

COM NO

DC

USER 1

Master

Slave

Conduit (in the ground)

Shielded cable
(3-wire)

Shield wire
Note: Do not connect the ground shield
wire at both ends.

Ground