Introduction

For information about troubleshooting the entire fabric, refer to the Fabric OS Troubleshooting and
Diagnostics Guide.

The Brocade DCX 8510-8 includes a number of diagnostic aids to assist with troubleshooting, including
LEDs on the hardware, commands that display current status, diagnostic tests for hardware and
software, and error messages. In addition, a number of managing and monitoring features are available,
such as Fabric Manager, Web Tools, Fabric Watch, and Advanced Performance Monitoring.

If the Brocade DCX 8510-8 does not operate as expected, the following steps can be taken to diagnose
the problem:

• Check the LEDs and refer to the LED tables (

Monitoring System Components

on page 47) for

interpretation and recommended actions.

• Review the results of the last POST run by the Brocade DCX 8510-8 (

Interpreting POST and boot

results

on page 146).

• Review the error logs. (Refer to the Fabric OS Troubleshooting and Diagnostics Guide for more

information).

Review RASlog entries.

Use the sensorShow command to determine the status of the hardware components.

Run diagnostic tests (

Diagnostics

on page 147).

Reboot the Brocade DCX 8510-8 or power the entire chassis off and then on (

Powering off

the Brocade DCX 8510-8

on page 46 and

Providing power to the Brocade DCX 8510-8

Backbone

on page 27).

If the problem is still unresolved after these steps, contact your support provider.

Obtaining chassis and component status

The CLI commands in the following table provide status and environmental information about the
chassis and its components. These commands provide information only, and they do not interrupt traffic
flow. For more information about these commands, refer to the Fabric OS Command Reference.