background image

Blower assembly LED descriptions (Continued)

TABLE 8

LED purpose Color

Status

Recommended action

Flashing amber (on 1/2
second, then off 3.5
seconds)

Fan is disabled.

Run the fanEnable command to
enable the fan.

Fast-flashing amber (on
1/2 second, then off 1/2
second)

Environmental range
exceeded.

Check for out-of-bounds
environmental condition, resolve any
problems, and reseat the unit. If the
LED continues to flash, replace the
unit.

Determining the status of a WWN card

Complete the following steps to determine the status of a WWN card.

NOTE
The WWN bezel (logo plate) covers the WWN cards.

1. Enter the chassisShow command to display information about the WWN card. (WWN units

correspond to information specific to the WWN card.) Error messages that may indicate problems
with a WWN card are summarized in the following table.

Messages that may indicate WWN card failure

TABLE 9

Type of message

Sample error message

WWN unit fails its field-replaceable
unit (FRU) header access.

0x24c (fabos): Switch: switchname, error EM-

I2C_TIMEOUT, 2, WWN 1 I2C timed out: state 0x4

WWN unit fails to power on.

<timestamp>, [EM-1004], <sequence-number>,,

CRITICAL, <system-name>, WWN # failed to power

onor<timestamp>, [EM-1043], <sequence-number>,,

WARNING, <system-name>, Can't power <FRU Id> <state

(on or off)>.

WWN unit is being faulted.

0x24c (fabos): Switch: switchname, Critical EM-

WWN_UNKNOWN, 1, Unknown WWN #2 is being

faultedor<timestamp>, [EM-1003], 40, SLOT 7 | FFDC

| CHASSIS, CRITICAL, Brocade_DCX, WWN 2 has unknown

hardware identifier: FRU faultedor<timestamp>,

[EM-1034], <sequence-number>,, ERROR, <system-

name>, WWN # set to faulty, rc=<return code>

WWN unit is not present or is not
accessible.

0x24c (fabos): Switch: switchname, Error EM-

WWN_ABSENT, 2, WWN #1 not presentor<timestamp>,

[EM-1036], <sequence-number>,, WARNING, <system-

name>, <FRU Id> is not accessible.

Writing to the FRU history log
(hilSetFruHistory) has failed.

0x24c (fabos): Switch: switchname, Error EM-

HIL_FAIL, 2, HIL Error: hilSetFruHistory failed,

rc=-3 for SLOT 3

WWN unit insertion was detected.

<timestamp>, [EM-1049], <sequence-number>,, INFO,
<system-name>, FRU WWN # insertion detected.