Interpreting post and boot results, Post, Interpreting post and boot – Brocade DCX 8510-8 Backbone Hardware Reference Manual User Manual

Page 146: Results

Advertising
background image

Environmental status and maintenance commands

TABLE 28

Command

Information displayed

sensorShow

Temperature readings for the port blades

Temperature readings for the CP blades

Status and RPM of all operational fans

Status of all operational power supplies

tempShow

Temperature readings for the port blades

Temperature readings for the CP blades

psShow

Status of all operational power supplies

fanShow

Status and RPM of all operational fans

chassisShow

Serial number, time awake, and additional information about each component

slotShow

Slot occupancy

errShowerrDump System error log. Refer to the Fabric OS Message Reference for more information on the

messages in this log.

Interpreting POST and boot results

The Brocade DCX 8510-8 performs Power-On Self-Test (POST) by default each time the chassis is
powered on, rebooted, or reset. The Brocade DCX 8510-8 can be rebooted using the reboot (to
reboot each CP individually) or fastBoot commands. The fastBoot command reboots the switches
without running POST. If the active CP blade is rebooted, it fails over to the standby CP blade.

POST

The Brocade DCX 8510-8 automatically performs POST each time it is powered on or reset.

To verify that POST has completed without error, do the following:

• Verify that all LEDs return to a normal state after POST completes.

If one or more LEDs do not return to a normal state, and this is not due to the Brocade DCX 8510-8
being set to beacon, refer to the relevant LED table to identify and correct the problem. For port
blades, and CP and core switch blades, the slotShow command can be used to check the status of
the slots. For information about turning beaconing on or off, refer to the Fabric OS Administrator's
Guide
.

• Verify that the switch prompt displays when POST completes.

If it does not display, POST was not successfully completed. Contact the Brocade DCX 8510-8
supplier for support.

• Review the system error log using the errShow or errDump commands.

Interpreting POST and boot results

146

Brocade DCX 8510-8 Backbone Hardware Reference Manual

53-1002180-07