8510-8 supplier to order replacement parts. Both physically absent or faulty could also be the result
of the power supply not being properly seated.

FIGURE 17 Blower assembly

1. Power LED
2. Fault LED

The following table describes the LED patterns for the blower assembly.

Blower assembly LED descriptions

TABLE 8

LED purpose Color

Status

Recommended action

Power

No light (LED is off)

Blower assembly does not
have power.

Ensure that the blower assembly is
firmly seated and has power.

Steady green

Blower assembly has power.

No action required.

Fault

No light (LED is off)

Blower assembly is either
healthy or does not have
power.

Ensure that the blower assembly has
power.

Steady amber

Blower assembly has a
failure (full or partial).

Replace the blower assembly.

Slow-flashing amber (on
2 seconds, then off 2
seconds)

Blower assembly is not
seated correctly or is faulty.

Pull the unit out and reseat it. If the
LED continues to flash, replace the
unit.