Disconnecting from network and fabric – Brocade DCX 8510-4 Backbone Hardware Reference Manual User Manual

Page 101

Advertising
background image

Manufacture: Day: 1 Month: 1 Year: 2007

Update: Day: 14 Month: 3 Year: 2012

Time Alive: 187 days

Time Awake: 3 days

<output truncated>

CHASSIS/WWN Unit: 1 (in same assembly as WWN Unit: 2)

Header Version: 2

Power Consume Factor: -3

Factory Part Num: 60-0001501-07

Factory Serial Num: FT02X805BE2

Manufacture: Day: 26 Month: 3 Year: 2007

Update: Day: 14 Month: 3 Year: 2009

Time Alive: 207 days

Time Awake: 3 days

<output truncated>

switch:admin>

6. Create a SAN "profile" by entering and recording the information provided by the following

commands:

nsShow
nsAllShow
switchShow -qsfp
fabricShow

Copy the command output into a text file named "SANbefor.txt." After the Brocade DCX 8510-4 is
restored to the fabric, this information can be used to verify that no unintentional changes have
occurred to the fabric.

switch:admin> nsshow

Enter Pid COS PortName NodeName TTL

<output truncated>

switch:admin> nsallshow

12 Nx_Ports in the Fabric

<output truncated>

switch:admin> switchshow

switchName: switch

<output truncated>

switch:admin> fabricshow

Switch ID Worldwide Name Enet IP Addr FC IP Addr Name

<output truncated>

switch:admin>

7. Enter supportShow; then copy the command output into a text file named "spptshow.txt."

NOTE
The supportShow command has a very long output and time for completion. It may last 20 minutes
or longer depending on the size of the SAN.

This file provides a backup of all the information that might be required by Technical Support. The
information can be used after the Brocade DCX 8510-4 is restored to the fabric to verify that no
unintentional changes have occurred to the fabric.

switch:admin> supportshow

version: 7.0.0

<output truncated>

switch:admin>

8. Record the cable connections between the Brocade DCX 8510-4 and the target device and ports.
9. Run supportSave on the active CP. The information recorded can be very important in case you

have difficulties during the replacement process.

Disconnecting from network and fabric

Complete the following steps to disconnect the chassis from the network.

Disconnecting from network and fabric