Brocade DCX 8510-4 Backbone Hardware Reference Manual User Manual

Page 60

Advertising
background image

Messages that may indicate WWN card failure (Continued)

TABLE 9

Type of message

Sample error message

WWN unit is being faulted.

0x24c (fabos): Switch: switchname, Critical EM-

WWN_UNKNOWN, 1, Unknown WWN #2 is being

faultedor<timestamp>, [EM-1003], 40, SLOT 7 | FFDC |

CHASSIS, CRITICAL, Brocade_DCX, WWN 2 has unknown

hardware identifier: FRU faultedor<timestamp>,

[EM-1034], <sequence-number>,, ERROR, <system-name>,

WWN # set to faulty, rc=<return code>

WWN unit is not present or is not
accessible.

0x24c (fabos): Switch: switchname, Error EM-

WWN_ABSENT, 2, WWN #1 not presentor<timestamp>,

[EM-1036], <sequence-number>,, WARNING, <system-

name>, <FRU Id> is not accessible.

Writing to the FRU history log
(hilSetFruHistory) has failed.

0x24c (fabos): Switch: switchname, Error EM-HIL_FAIL,

2, HIL Error: hilSetFruHistory failed, rc=-3 for SLOT

3

WWN unit insertion was detected.

<timestamp>, [EM-1049], <sequence-number>,, INFO,

<system-name>, FRU WWN # insertion detected.

WWN unit removal was detected.

<timestamp>, [EM-1050], <sequence-number>,, INFO,

<system-name>, FRU WWN # removal detected.

The following figure displays the WWN bezel (logo plate). The WWN cards are under the bezel.

FIGURE 18 WWN bezel (logo plate) for DCX-4S and DCX 8510-4

Monitoring System Components

60

Brocade DCX 8510-4 Backbone Hardware Reference Manual

53-1002177-07