Brocade DCX 8510-4 Backbone Hardware Reference Manual User Manual
Page 129
Advertising
‐
The Link Cost is equal to the sum of all established/low metric (or currently active) circuits’
MAX rates in the tunnel
‐
Fabrics connected through FCIP merge if the ports are configured as VE_Ports, and do not
merge if they are configured as VEX_Ports. If VE_Ports are used in a Fibre Channel
Routing Services backbone fabric configuration, then the backbone fabric merges, but the
EX_Port-attached edge fabrics do not merge. For more information, refer to the Fabric OS
Administrator's Guide
• Up to three FC trunking groups:
‐
Trunk group 0: FC ports 0, 1
‐
Trunk group 1: FC ports 6, 7
‐
Trunk group 2: FC ports 2, 3, 4, 5, 8, 9, 10, 11
Application and Encryption Blades
Brocade DCX 8510-4 Backbone Hardware Reference Manual
129
53-1002177-07