Installation of the brocade dcx 8510-4, Time and items required – Brocade DCX 8510-4 Backbone Hardware Reference Manual User Manual

Page 23

Advertising
background image

Installation of the Brocade DCX 8510-4

Time and items required................................................................................................. 23

Preparing for the Brocade DCX 8510-4 installation........................................................ 24

Unpacking and installing the Brocade DCX 8510-4........................................................ 25

Items included with the Brocade DCX 8510-4................................................................ 26

Providing power to the Brocade DCX 8510-4 Backbone................................................ 27

Port numbering................................................................................................................27

Chassis slots................................................................................................................... 29

Cable management.........................................................................................................29

Time and items required

You can set up and install the Brocade DCX 8510-4 in the following ways:

• As a standalone unit on a flat surface.
• In a 19-in. Electronic Industries Association (EIA) cabinet, using a Brocade DCX 8510-4, DCX-4S

Rack Mount Kit (either a 27-31 in. or 18-24 in. kit depending on rack used).

• In a chassis with the Port Side Exhaust Kit (provided) in an approved rack.
• In a mid-mount telecommunications (Telco) rack, using the Mid-Mount Rack Kit available from your

Brocade DCX 8510-4 supplier.

This chapter describes how to set up the Brocade DCX 8510-4 as a standalone unit. For rack-mount
installation instructions, refer to the appropriate manual as described in the following table.

The following table describes the main installation and setup tasks, the estimated time required for
each, and the items required to complete the task based on a fully populated Brocade DCX 8510-4 (256
Fibre Channel ports using the FC16-64 port blades). Configurations with fewer ports require less time.
These time estimates assume a prepared installation site and appropriate power and network
connectivity.

Installation tasks, time, and items required

TABLE 2

Installation task

Time estimate

Items required

Site preparation and unpacking
Brocade DCX 8510-4

30 minutes

1/2-in. socket wrench (to remove pallet bolts).

Pallet jack.

Hydraulic lift or assisted lift, able to raise to a minimum of
140 cm (55 in.), with a minimum capacity of 113 kg (250 lb).
The Brocade DCX 8510-4 weighs 68 kg (150 lb) with four
FC16-48 port blades installed (192 ports).

Installing rack mount kit or Port
Side Exhaust Kit

30 minutes

Refer to the one or more of the following if you are mounting
the Brocade DCX 8510-4 in a rack: Brocade Port Side
Exhaust Kit Installation Procedure, Mid-Mount Rack Kit
(Backbone) Installation Procedure,
or 27-31 Inch Rail Rack
Mount (Backbone) Kit Installation Procedure
.

Mounting and securing Brocade
DCX 8510-4 in rack

30 minutes