background image

specific and detailed process. Read the directions under

Downloading firmware from an FTP server

on

page 75 or

Downloading firmware from a USB device

on page 76 carefully.

NOTE

If the new CP blade does not have the same firmware as the active CP blade, the new blade must be
upgraded to the same firmware version. You can determine the firmware version on the replacement
blade and perform a firmware upgrade if necessary after inserting the blade in the chassis, but you
must disable high availability (HA) before inserting the new blade. If the new CP blade is severely
down-level, a very specific procedure must be followed to bring the blade up to the correct firmware
version.

Time and items required

The replacement procedure for the CP blade takes approximately 30 minutes. The following items are
required for the CP blade replacement:

• Electrostatic discharge (ESD) grounding strap
• Workstation computer
• Serial cable
• IP address of an FTP server for backing up the Brocade DCX 8510-4 configuration
• #2 Phillips screwdriver
• Replacement Brocade DCX 8510-4 control processor blade (CP8)

If you are upgrading through multiple versions of the Fabric OS, consult the

Table 10

on page 74

table to see which intermediate versions of the Fabric OS you might need. Plan carefully and for extra
time if this is your situation.

Faulty CP blade indicators

Confirm that you need to replace the CP blade. The following events may indicate that a CP blade is
faulty:

• The status LED on the CP blade is lit steady amber, or the power LED is not lit.
• The CP blade does not respond to Telnet commands, or the serial console is not available.
• The slotShow command does not show that the CP blade is enabled.
• The haShow command indicates an error.
• The clock is inaccurate, or the CP blade does not boot up or shut down normally.
• Any of the following messages display in the error log:

"Slot unknown" message relating to a CP slot

CP blade errors or I2C timeouts

FRU: FRU_FAULTY messages for a CP blade

Configuration loader messages or "Sys PCI config" messages

Generic system driver messages ("FABSYS")

Platform system driver messages ("Platform")

EM messages that indicate a problem with a CP blade

Function fail messages for the CP master

For more information about error messages, refer to the Fabric OS Message Reference.

Time and items required