Power supply LED descriptions

TABLE 7

LED purpose Color

Status

Recommended action

Power

No light (LED is
off)

Power supply does not have
incoming power and is not
providing power to the Brocade
DCX 8510-4.

Ensure that the power supply is firmly
seated, the Brocade DCX 8510-4 has
incoming power, both power cables
are connected, and AC power
switches are on.

Steady green

Power supply has incoming
power and is providing power to
the Brocade DCX 8510-4.

No action required.

Flashing green

Power supply is about to fail.

Replace the power supply.

Determining the status of a blower assembly

Complete the following steps to determine the status of a blower assembly.

1. Check the LED indicators on the blower assembly. The LED patterns may temporarily change

during POST and other diagnostic tests; for information about how to interpret the LED patterns,
refer to the following table. The Brocade DCX 8510-4 has two blowers. Be sure to check each
module.

2. Check the blower assembly status using the fanShow command.

The status for each blower assembly displays OK, Absent, or Faulty. The RPM of each fan in the
assembly is also provided. If a blower assembly displays absent or faulty, contact the Brocade DCX
8510-4 supplier to order replacement parts. Both physically absent or faulty could also be the result
of the power supply not being properly seated.

FIGURE 17 Blower assembly

1. Power LED
2. Fault LED

The following table describes the LED patterns for the blower assembly.