Replacing a qsfp transceiver, Blades, Refer to – Brocade DCX 8510-4 Backbone Hardware Reference Manual User Manual

Page 92: Inter-chassis link (icl) cable removal and, Replacement

Advertising
background image

Replacing a QSFP transceiver

Complete the following steps to replace a QSFP transceiver.

1. If the QSFP transceiver is being replaced, grasp the bail of the new QSFP and push the QSFP into

the connector on the blade until it is firmly seated. The QSFP is keyed to fit into the connector in
one way. The status LED initially blinks amber after installation, then displays steady amber.

2. Grasp the QSFP cable by the rubber housing and push it into the QSFP transceiver until it is firmly

seated. The cable housing is keyed to fit into the QSFP in one way.

The status LED displays steady amber until both ends of the cable are inserted and the link is
established. When the link is fully established, the LED displays steady green.

3. Repeat for each cable that requires replacement.

Once all the cables are attached, refer to the Fabric OS Administrator's Guide for the configuration
procedure.

Qualified transceivers for the FC16-64 port blade and the core blades

The following table shows the qualified transceivers for the FC16-64 port blade and the core blades.

Qualified transceivers for FC16-64 port blade and the core blades

TABLE 12

Brocade part
number

Part type

Cable length

Port speeds

Supported blades

57-1000294-01

QSFP transceiver 100 m OM4

Auto-negotiable 4-, 8-,
and 16-Gbps

FC16-64

57-1000267-01

QSFP transceiver 100 m OM4

Only fixed 16-Gbps

CR16-4/8

57-0000090-01

QSFP transceiver 50 m OM3

NOTE
The QSFP transceivers supported on FC16-64 port blade are not interchangeable with QSFP
transceivers supported on the core blades.

Inter-chassis link (ICL) cable removal and replacement

Use this procedure to remove and replace ICL QSFP cables. Follow these guidelines while removing
and replacing ICL QSFP cables.

• The QSFP ports on the core switch blades can be used only with an inter-chassis link (ICL) license.

After the addition or removal of a license, the license enforcement is performed on the ports only
when the portdisable and portenable commands are issued on the ports. An ICL license must be
installed on all Brocade Backbones forming the ICL connection. Beginning with Fabric OS v7.0.1,
up to nine neighboring Brocade DCX 8510 series chassis can be connected with the QSFP cables.
Under Fabric OS v7.0.0, six chassis can be connected.

• For the Brocade DCX 8510 Backbones, an off-the-shelf QSFP cable up to 50 meters long can be

used as an ICL cable.

• For the Brocade DCX 8510 Backbones, if the QSFP cables are not used, make sure the rubber

gaskets are in the QSFP transceivers.

Replacing a QSFP transceiver

92

Brocade DCX 8510-4 Backbone Hardware Reference Manual

53-1002177-07