Fieldwork

71

b.

Tap

,QVHUW« and

enter a new point
using the

General

and

Location

cards with the

following values, as
shown:

Point Name

:

2

Northing

:

5050

Easting

:

5050

Elevation

:

100

Description

:

Backsight

and then tap OK.

4.

Set up your backsight. In this example, we will
setup on Point 1 and backsight Point 2, which was
just created.

a.

Access the

6XUYH\ , %DFNVLJKW 6HWXS screen.

b.

In the

Occupy

Point

field, enter

1

as the point

name.

Tip: You can also select an existing point from a map
view or from a list by using the

power button.

c.

Enter an

HI

and

HR

of

5

feet each.

d.

Toggle the



%6 'LUHFWLRQ



/



%6 3RLQW



button to

%6 3RLQW



and enter

2

as the point name.

e.

Leave the

Fixed HR at Backsight

field unchecked.

f.

Confirm that the

Backsight Circle

value is zero. If it displays a

non-zero value, tap the



&LUFOH«



button and set it to zero.