Spectra Precision Survey Pro v3.80 Recon iPAQ User Manual User Manual

Page 88

Advertising
background image

User’s Manual

80

g.

Assuming the rod has been repositioned, take another shot by
tapping the

6KRW



button and enter the following new shot

data:

Angle Right

:

45

Zenith

Angle

:

90

Slope

Dist

:

70.8

and then tap OK to continue.

h.

The rod must now move

FORWARD

by

0.089

feet

to be over the design point. We will assume that
this is close enough and will store the point from
this shot by tapping the

6WRUH« button.

i.

Enter the following point information:

Point Name

:

5

Description

:

Staked

and tap

6WRUH . This will

return you to the first Point Stake screen.

5.

Stake the next design point.

a.

We want to stake the next design point in the
project. We can do this by entering

3

in the

Design

Point

field and then pressing

6ROYH ! , or we can

simply tap

1H[W 3RLQW ! , which will automatically

advance the current design point by the increment
value and solve automatically. Either method will
send you to the second Stake Points screen.

b.

The information needed to locate the next design
point is displayed. When connected to a total
station, you would turn the total station
horizontally to 115°00’00”, vertically to 90°00’00”
and send the rod man out about 100 feet before
continuing. Tap the



6WDNH !



button to continue

to the third screen.

c.

Tap the

6KRW button and enter the following shot data:

Angle Right

:

115

Zenith

:

90

Slope

Dist

:

99.8

and then tap OK to continue.

Advertising