Introduction

SLC Capacity

CP355 - An addressable ionization smoke detector which measures the level of combustion
products in its chamber using the ‘ionization principle’.
D350P - An addressable photoelectric duct detector. The D350RP includes an alarm relay. Air
velocity rating is 500 to 4,000 feet per minute.
D350PL -An addressable low flow photoelectric duct detector (D350PLA for Canada). The
D350RPL includes an alarm relay (D350RPLA for Canada). Low Flow refers to the air velocity
rating of 100 to 4,000 feet per minute (0.5 to 20.32 m/sec).
D355PL - An addressable non-relay photoelectric low flow smoke detector. Low Flow refers to
the air velocity rating of 100 to 4,000 feet per minute (0.5 to 20.32 m/sec).
H350

1

- An addressable detector using a thermistor sensing circuit for fast response. H350R

incorporates a thermal rate of rise of 15°F (9.4°C)/minute.
H355

1

- An addressable 135° fixed temperature heat detector using a thermistor sensing circuit for

fast response. H355R incorporates a thermal rate of rise of 15° F (9.4° C)/minute.
H355HT

1

- An addressable 190° fixed temperature heat detector using a thermistor sensing circuit

for fast response.
SD350 - An addressable photoelectric smoke detector which provides smoke sensing utilizing
optical sense technology. The SD350T includes a 135° F fixed thermal sensor.
SD355 - An addressable photoelectric smoke detector which provides smoke sensing utilizing
optical sense technology. The SD355T includes a 135° F fixed thermal sensor. The SD355R is a
low profile, intelligent, photoelectric sensor that is remote test capable.
BEAM355 - An addressable long range projected beam smoke detector designed to provide open
area protection. The BEAM355S has an integral sensitivity test feature that consists of a test filter
attached to a servomotor inside the detector optics.
DNR(W) - Innovair Flex, intelligent, non-relay, low flow, photoelectric duct detector housing.
This requires the SD355R photoelectric smoke detector. Accomodates the installation of the CRF-
300 relay module. The DNRW is a watertight housing.

1.4.7 Manual Pull Station

The BG-12LX is a dual-action pull station that, when activated, provides an addressable
identification and its location to the control panel. An addressable monitor module is mounted
inside the pull station to facilitate servicing and replacement.

1.4.8 300 Series Addressable Devices

Fire•Lite’s 300 Series of addressable devices are fully compatible with the MS-9200, MS-9200UD,
MS-9200UDLS, MS-9600, MS-9600LS(C/E), MS-9600UDLS/E, and MS-9050UD FACPs. The
devices must be configured for CLIP (Classic Loop Interface Protocol) Mode operation. The
address of 300 series devices cannot be set above 99. Compatible devices include:

1.5 SLC Capacity

The protocol selected for an SLC loop determines the maximum number of devices that can be
handled by the loop. See Section 1.3, “Polling Protocols”, on page 10. Within those limits, the
individual control panel may have additional restrictions. See the specific installation manual for
this information.

1. Addressable Heat Detectors are not compatible with the MS-9200(E).

• SD300 Photo

• M300 Monitor Module

• SD300T Photo w/Thermal

• M301 Mini Monitor Module

• CP300 Ionization

• M302 2-wire Monitor Module

• BG-10LX Pull Station

• C304 Control/Relay Module