FireLite SLC Wiring Manual — P/N 51309:P1 10/12/2011

Appendix E: Canadian Versions of SLC Devices

UL-listed SLC Device

ULC-listed SLC Device

Description

AD350/AD355

AD350A/AD355A

Intelligent detector that combines a photoelectric sensing chamber
and fixed temperature heat detection (135°F/57.2°C).

CP350/CP355

CP350A/CP-355A

Addressable, intelligent smoke detector that incorporates an
ionization sensing chamber. Designed to provide open area
protection.

SD350/SD355

SD350A/SD355A

Addressable intelligent smoke detector that uses a photoelectric
sensing chamber. Listed for use in ducts. Designed to provide open
area protection.

SD350T/SD355T

SD350TA/SD355TA

Adds thermal sensors that will alarm at a fixed temperature of
135°F (57°C).

H350/H355

H350A/H355A

Intelligent thermistor sensing circuit for fast response. Designed to
provide open area protection with 50 foot spacing capability. A fixed
temperature sensor with 135°F fixed temperature alarm.

H350R/H355R

H350RA/H355RA

Incorporates a thermal rate of rise of 15°F (9.4°C).

H355HT

H355HTA

High temperature sensor with 190°F (87.8°C) fixed temperature
alarm.

Photoelectric Duct Detector, Low-flow. Requires
SD350(A)/SD355(A) detector.

Bases

B210LP

B210LPA

Standard U.S. Low-Profile base (6", 15.24 cm).

B501

B501A

Standard European flangeless base (4", 10.16 cm).

B501BH, B501BHT

B501BHA, B501BHTA

Sounder base, includes Sounder base with temporal sounder (UL
8th Edition).

B501BH-2, B501BHT-2

N/A

Sounder base, includes Sounder base with temporal sounder (UL
9th Edition).

B224RB

B224RBA

Low Profile Intelligent relay base.

B224BI

B224BIA

Low Profile Intelligent isolator base.

B200SR

B200SRA

Intelligent sounder base, temporal or steady.

Monitor and Zone Interface Modules

MMF-300

MMF-300A

Used for normally open contact alarm initiating devices, such as
manual pull stations, four-wire smoke detectors, heat detectors,
waterflow, and supervisory devices.

MMF-302

MMF-302A

Used to interface with two-wire smoke detectors in addition to
normally open contacts.

MDF-300

MDF-300A

Two independent 2-wire Initiating Device Circuits (IDCs) at two
separate, consecutive addresses. Wire supervised IDCs as NFPA
Style B (Class B) or Style D (Class A) circuits. The modules come
with a thermoplastic cover for mounting to a 4-inch (10.16 cm)
square mounting box.

MMF-301

MMF-301A

Functionally similar to the MMF-300 Monitor Module, but offered in
a smaller package for mounting directly in the electrical box of the
device being monitored. (Class B input circuit only.)

BG-12LX

BG-12LX

An addressable manual pull station with key-lock reset feature. The
addressable module is housed within the pull station.

Control Modules

CMF-300

CMF-300A

Control Module, NAC: Addressable Control Module used as
Notification Appliance Circuits (NACs) to power and supervise
compatible, UL-listed notification appliances. Wired supervised
NACs as NFPA Style Y (Class B) or Style Z (Class A). The modules
come with a thermoplastic cover for mounting to a 4-inch (10.16
cm) square mounting box.