6-3 parameters recorded – KYORITSU 6305 Instruction Manual User Manual

Page 111

Advertising
background image

KEW6305

8.14

8-6-3 Parameters recorded

● Parameters to be saved

Parameters to be saved

Voltage

(RMS)

Vi

: voltage of each phase

Vi max : max. Vi values
Vi min : min. Vi values
Vi avg : avg. Vi values

Current

(RMS)

Ai

: current of each phase

Ai max : max. Ai values

Ai min : min. Ai values

Ai avg : avg. Ai values

Active

power

P

: total active power

Pi

: active power of each phase

P max : max. P value

Pi max : max. Pi values

P min

: min. P value

Pi min : min. Pi values

P avg

: avg. P value

Pi avg : avg. Pi values

Reactive

power

Q

: total reactive power

Qi

: reactive power of each phase

Q max : max. Q value

Qi max : max. Qi values

Q min : min. Q value

Qi min : min. Qi values

Q avg

: avg. Q value

Qi avg : avg. Qi values

Apparent

power

S

: total apparent power

Si

: apparent power of each phase

S max : max. S value

Si max : max. Si values

S min

: min. S value

Si min : min. Si values

S avg

: avg. S value

Si avg : avg. Si values

Power factor

PF

: power factor of whole system PFi

: power factor of each phase

PF max : max. PF value

PFi max : max. PFi values

PF min : min. PF value

PFi min : min. PFi values

PF avg : avg. PF value

PFi avg : avg. PFi values

Frequency

f

: frequency of V1

f max

: max. f value

f min

: min. f value

f avg

: avg. f value

Neutral

current

In

: current on neutral line

In max : max. In value

In min : min. In value

In avg : avg. In value

Active

energy

(consumption)
(regenerating)

(overall)

+WP

: total active energy (consumption)

+WPi

: active energy (consumption) of each phase

-WP

: total active energy (regenerating)

-WPi

: active energy (regenerating) of each phase

#WP

: total active energy (overall)

#WPi

: active energy (overall) of each phase

Apparent

energy

(consumption)
(regenerating)

(overall)

+WS

: total apparent energy (consumption)

+WSi

: apparent energy (consumption) of each phase

-WS

: total apparent energy (regenerating)

-WSi

: apparent energy (regenerating) of each phase

#WS

: total apparent energy (overall)

#WSi

: apparent energy (overall) of each phase

Reactive

energy

(consumption)

+WQ

: total reactive energy (consumption)

Demand

value

#DEM : total demand value

#DEMi : demand value of each phase

TARGET : target demand value

* i = 1, 2, 3

where, “max.” and “avg.” mean maximum and average values during an interval.