7.5

KEW6305

● Automatic measurement at a preset time and date

1

Preset the start time and date on

SET UP

range.

2

Set the Function switch to

Wh

range, and press the

START/STOP

key.

3

The file number screen is displayed for about 1 sec. (a file is opened), followed by the measurement

screen. The instrument goes into stand-by mode. LED status indicator flicker while the instrument is
in

stand-by

mode.

File number screen

(displayed for about 1 sec.)





Measurement screen



4

The survey starts at the preset time and date, and the LED status indicator stop flickering and are
permanently on.








NOTE:

* The start time and date should be set after the current time in such a way to give enough time to the

user to complete all settings before the survey starts.

* When the start time and date are set before the current time, measurement starts immediately upon

pressing the

START/STOP

key.

* If the preset start time and date come after the preset stop time and date, the survey cannot be done.
* Even if the start and stop time have been preset and the instrument is in standby mode, pressing the

START/STOP

key at least 2 sec. releases the stand-by mode and start a survey in Manual mode. This

renders the start/ stop time and date settings ineffective.