Specification, 1 general specification – KYORITSU 6305 Instruction Manual User Manual

Page 130

Advertising
background image

13.1

KEW6305

13.Specification

13.1 General specification

Location for use

: In door use, Altitude up to 2000m

Temperature & humidity range : 23ºC±5ºC, Relative humidity 85% or less
(guaranteed accuracy)

(no condensation)

Operating Temperature &

: 0ºC±40ºC, Relative humidity 85% or less

humidity range

(no condensation)

Storage Temperature &

: -20ºC±60ºC, Relative humidity 85% or less

humidity range

(no condensation)

Measured line

: single-phase 2-wire (1ch ~ 3ch), single-phase 3-wire, three-phase 3-wire,

three-phase 4-wire

Insulation resistance

: 50MΩ or more / 1000V

between (Voltage/Current input terminal, Power connector) and (Enclosure)

Indication renewal

: every 1 sec

Applicable standards

: IEC61010-1, -2-030 Measurement CAT. III 600V Pollution degree 2,

IEC 61010-031, IEC61326

Dimension

: 175(L) x 120(W) x 65(D) mm

Weight

: approx 900g (including batteries)

Accessories

: Voltage test leads M7141B (red/ green/ black, blue w/alligator clip) x 1 set

Power cord M7170 x 1 pce

Alkaline size AA battery (LR6) x 6 pcs

CD-ROM x 1 pce

- Communication software (KEW Windows for KEW6305)

- Instruction manual (PDF file)

USB cable M7148 (with Filter) x 1 pce

Carrying case M9125 x 1 pce

Quick manual x 1 pce

SD card x 1 pce

Optional parts

: SD card 2GB (M-8326-02)

M-8128(Clamp sensor 50A Φ24mm)
M-8127(Clamp sensor 100A Φ24mm)
M-8126(Clamp sensor 200A Φ40mm)
M-8125(Clamp sensor 500A Φ40mm)
M-8124(Clamp sensor 1000A Φ68mm)
M-8129(Flexible sensor 3000A Φ150mm)
Power supply adopter M-8312
Carrying case (for instrument) M-9132

Advertising