132 TrueCopy for the XP128/XP1024/XP10000/XP12000

NOTE:

The copy pending timeout setting for the group determines the maximum amount of time

that the suspend/drain operation can take.

3.

When the status for all TC390A pairs in the group has changed to suspended, the duplicate set of

volumes is complete. If needed, you can restart the application at the main site.

Powering Off/On TrueCopy Components

The user is responsible for controlling power-off activities for disk arrays involved in TC390 operations. If

you need to power off the XP128/XP1024/XP10000/XP12000, call your HP representative or HP

technical support for assistance. This section provides instructions for performing planned outages of

TC390 components.
If power is removed from an MCU while TC390 operations are in progress, the TC390 pairs are not

affected, but the update sequence consistency of the TC390A groups at the RCU may be affected. For

more information, see

Planned Outage of the MCU

” on page 133. When power is restored to an MCU,

the MCU communicates with its RCU(s) to confirm the pair status of the R-VOLs. Verify that TC390

communications are fully restored (all RCU paths have normal status) before beginning I/O operations to

the M-VOLs. If the MCU accepts a write I/O operation for an M-VOL before this confirmation is complete,

the MCU will suspend the pair and change the status of the M-VOL to suspended-by RCU (the MCU will

not be able to change the pair status of the R-VOL).
If power is removed from an RCU or remote copy connection while TC390 operations are in progress, the

MCU(s) will detect the communication failure, suspend all affected pairs, and generate SIMs and console

messages reporting the failures. The MCU will change the status of the M-VOLs to suspended-by RCU, but

will not be able to change the status of the R-VOLs.

NOTE:

If an MCU/RCU is powered off and its backup batteries are fully discharged while TC390 pairs

are suspended, the M-VOL/R-VOL cylinder maps will not be retained. In this unlikely case, the MCU/RCU

will mark all cylinders of all suspended TC390 volumes as modified so that the MCU will perform the

equivalent of an entire initial copy operation when the pairs are resumed. (The R-VOL cylinder map is used

only for TC390A operations.)

Planned Outage of the MCU

A planned MCU outage does not affect TC390 Synchronous pairs. For TC390A operations, the MCU must

communicate with the RCU even when there are no M-VOL update I/Os from the primary system. During

the power-off sequence, the MCU will automatically suspend all TC390A pairs in the duplex and duplex

pending state (suspend type = MCU P/S-OFF). During power-on-reset sequence, the MCU will

automatically resume these suspended pairs (pairs with other suspend types are not automatically

resumed).
If a TC390A group contains M-VOLs in the MCU being powered off and in other MCU(s) that is/are not

being powered off, the pairs behind the other MCU(s) will not be suspended and will continue to be

updated.

To maintain a fully consistent group at the RCU during the planned MCU outage:

1.

Disable the applications using all M-VOLs in the consistency group.

2.

Suspend the group at the RCU using the Group suspend option. You can use the Purge or Drain

suspend option because the M-VOL updates have stopped.

3.

Perform the planned outage of the TC390 MCU.

4.

When the MCU is fully powered on and ready to resume operations, resume the TC390A pairs at all

MCUs that were powered off (use the resume group option).

Planned Outage of the RCU or Remote Copy Connection

You must suspend all affected TC390 pairs prior to a planned outage of an RCU or of a remote copy