Suspended truecopy asynchronous pairs, 12 truecopy asynchronous suspension conditions, Suspended – HP StorageWorks XP Remote Web Console Software User Manual

Page 40: Truecopy asynchronous pairs, Table 11

Advertising
background image

40

TrueCopy for the XP128/XP1024/XP10000/XP12000

Suspended TrueCopy Asynchronous Pairs

TC390A operations involve additional suspension conditions related to the asynchronous recordset

operations. Both the MCU and RCU can detect TC390A suspension conditions and suspend TC390A

pairs. The following table describes the TC390A suspension conditions and indicates which CU detects the

condition and which volume pairs are suspended. The TC390A offloading timer asynchronous option (see

Asynchronous Copy Option

” on page 102) and timeout group options (see ”

Adding Consistency Groups

(Add CT Group)

” on page 99) are used to control the TC390A suspension conditions. For troubleshooting

information for TC390A suspension conditions, see

Table 29

on page 146.

MCU P/S-OFF

R-VOL

(TC390A only)

The RCU received a request from the MCU to suspend the R-VOL due to

MCU power-off. The RCU stops expecting recordsets from that MCU.

by sidefile

overflow

M-VOL, R-VOL

(TC390A only)

The amount of sidefile exceeds the specified “current pending update

data rate” and the RCU data is not transferred within the specified

“offloading timer”.

Table 11

Consistency status for suspended TrueCopy Async R-VOLs

Consistency

Status

Description

Volume

This TC390A volume pair was probably suspended alone. Update sequence consistency

between this R-VOL and other R-VOLs in this consistency group is not ensured. This R-VOL cannot

be used for disaster recovery at the secondary system. This status is indicated when:
This volume pair was suspended due to a failure that did not affect the entire consistency group

and the Error Level pair option for this pair is set to

Volume.

This volume pair was suspended by a user-initiated suspend pair operation with the TC390A

Suspend (Async) suspend option set to Volume.

Group

This TC390A volume pair was suspended along with the other pair in its consistency group.

Update sequence consistency between this R-VOL and other R-VOLs in this consistency group is

ensured. This R-VOL can be used for disaster recovery at the secondary system after deleting the

TC390 volume pair from the RCU. This status is indicated when:
All volume pairs in this consistency group were suspended due to a failure that affected the

entire consistency group, not just one pair (for example, MCU-RCU communication failure).
The volume pair was suspended due to a failure that did not affect the entire group and the Error

Level TC390A pair option for this pair is set to Group.
This volume pair was suspended by a user-initiated suspend pair operation with the TC390A

Suspend (Async) suspend option set to Group.

Table 10

Suspend types (continued)

Suspend Type

Applies to

Description

Table 12

TrueCopy Asynchronous suspension conditions

Suspension Condition

Detected by

TC390A Pairs to be Suspended

The MCU could not send a pending recordset to the

RCU before the offloading timer asynchronous option

expired. See ”

Inflow Control of Recordsets

” on

page 32.

MCU

All TC390A pairs with M-VOLs in the

MCU.

During MCU power-on, the MCU could not establish

communication with the RCU before the RCU ready

timeout group option expired. See ”

Group Options” on

page 35

.

MCU

All TC390A pairs with M-VOLs in the

MCU.

The RCU could not settle a pending recordset before

the copy pending timeout group option expired.

RCU

All TC390A R-VOLs in the consistency

group.

The RCU could not communicate with the MCU before

the copy pending timeout group option expired.

RCU

All TC390A R-VOLs in the consistency

group.

Advertising