To add a new logical path from the connected MCU to an existing RCU:

1.

From the CU Number tree on the RCU Operations window, verify the correct CU image is selected.

2.

From the MCU/RCU list on the RCU Operations window, select the RCU to which you want to add a

path.

3.

Right-click to display the pop-up menu, click Edit SSID(s) & Path(s), and then click Add Path (see

Figure 52

). The Add Path window is displayed.

Figure 52

Opening the Add Path window

4.

From the Add Path window, enter the new path(s).

5.

Click Set in the Add Path window to set the paths. The list changes to the Path Settings Parameter list.

NOTE:

The options can be modified and/or canceled after you have set them. See ”

Modifying

Parameters and Omitting Selected Settings

” on page 95.

6.

Click Apply on the TrueCopy main window. The MCU will automatically begin using the new logical

path for TC390 activities.

Before deleting a path to an RCU, verify that the remaining number of paths will be equal to or greater

than the minimum number of paths setting (selected on the RCU Option window). The delete path

operation will fail if the number of remaining paths is less than the minimum number of paths.

To delete a path from the connected MCU to an existing RCU:

1.

Open the RCU Option window and check the minimum number of paths setting. If the remaining

number of paths will be less than this value, the delete path operation will fail. If needed, change the

minimum number of paths so that you can delete the appropriate path.

2.

From the CU Number/Port tree on the RCU Operations window, verify the correct CU image is

selected.

3.

From the MCU/RCU list on the RCU Operations window, select the RCU with the path you want to

delete.

4.

Right-click to display the pop-up menu, click Edit SSID(s) & Path(s), and then click Delete Path. The list

changes to the Path Settings Parameter list. Only the selected RCUs are listed.