Figure 6 dummy pair mode, 6 dummy pair mode – HP StorageWorks XP Remote Web Console Software User Manual

Page 34

Advertising
background image

34

TrueCopy for the XP128/XP1024/XP10000/XP12000

In the following figure, updates to the primary volume (A) are transferred to the device addresses of its

secondary volume (A’) as well as the secondary volumes of dummy volume pairs (B’-D’) in parallel.

Figure 6

Dummy pair mode

The basic specifications for dummy pair mode are:

Up to three dummy pairs can be related to one real volume pair.

Volumes must be assigned in both the MCU and RCU for dummy pair.

Custom-size volumes of minimum size (one cylinder) can be used for dummy pair.

Dummy pair volumes cannot accept host I/Os, must be offline from all host systems.

Volumes for a dummy pair must be in the same logical CU image as the real pair.

The following table shows the main differences between dummy pair mode and HPAV operations.

General recommendation: When a specific TC390A volume could be a bottleneck due to high write I/O

activity:

If write I/Os are from independent I/O requester, consider dividing I/O activity to different volume (by

dataset relocation, for example).

Otherwise consider using TC390A dummy pair(s).

You can use the PPRC CESTPAIR command as follows to establish TC390A dummy pairs and relationships

to real volume pairs. For detailed information on configuring master and dummy pairs using the CESTPAIR

TSO command, see ”

CESTPAIR

” on page 152.

1.

CESTPAIR: Establish real volume pair (A-A’)

2.

CESTPAIR: Establish 1st dummy pair (B-B’) for A-A’

3.

CESTPAIR: Establish 2nd dummy pair (C-C’) for A-A’

4.

CESTPAIR: Establish 3rd dummy pair (D-D’) for A-A’

Table 8

Differences between TC390A dummy pair mode and HPAV

TC390A Dummy Pair

HPAV

Paralleling

TC390 Async RIO

Host I/O

Effective for

Single or independent I/O requester

Independent I/O requester (for example, Different job

and extend). Due to this reason, possibly HPAV is not

effective for IMS® WADS.

Requires

At least minimum capacity VSC custom

volume

Only LDEV address