Figure 51 add path window (for fibre), 51 add path window (for fibre) – HP StorageWorks XP Remote Web Console Software User Manual

Page 91

Advertising
background image

TrueCopy for z/OS user guide

91

4.

From the MCU/RCU list on the RCU Operations window, select the RCU that you want to delete.

5.

Right-click to display the pop-up menu, click RCU Operation, and then click Delete RCU.

6.

Click Apply on the TrueCopy main window.

Adding and Deleting Logical Paths for an RCU (Add Path and Delete Path)

Before adding a path to an RCU, verify that the remote copy connection is properly installed, that the

appropriate MCU ports are configured as RCPs (serial) or Initiator ports (fibre), and that the appropriate

MCU CU image is selected. You can add up to four RCUs to each MCU CU image and establish up to

eight paths to each RCU. When you add a path to an RCU, TC390 will automatically start using the new

path to perform TC390 copy activities.
When the Add Path command is selected, the Add Path window is displayed. Use the Add Path window to

set the path(s) to an RCU.

Figure 51

Add Path window (for Fibre)

The MCU-RCU Path box includes:

The MCU Port boxes, which you use to enter the MCU port number. The Initiator and the RCP are listed

in the list and can be selected.

The RCU Port boxes, which you use to enter the RCU port number. The RCU Target port must be

specified.

The Link Address boxes, which you use to enter the Link Address.

The Cancel button cancels the settings you made. The Set button applies the settings you made and

changes the list.

NOTE:

The number of effectively displayed boxes depends on the number of paths that can be added.

For more information on the path status, refer to

Table 27

on page 143.

Advertising