HP StorageWorks XP Remote Web Console Software User Manual

Page 202

Advertising
background image

202 TrueCopy for the XP128/XP1024/XP10000/XP12000

The operating system must support the new DONOTBLOCK option.

Mode 61 must be ON.

If Mode 61 is OFF (default), the XP128/XP1024/XP10000/XP12000 performs current load

balancing control. If the operating system does not support the DONOTBLOCK option, set Mode 61 =

OFF.

DONOTBLOCK option: The XP128/XP1024/XP10000/XP12000 does not block write I/Os for the

specified logical device, to avoid performance impact for application programs.

CAUTION:

If you specify the DONOTBLOCK option for too many devices, a sidefile puncture condition

will occur. Use caution when determining the appropriate tuning (devices with DONOTBLOCK option, SVP

modes) for your operational environment.

Load balancing control for sidefile: When the DONOTBLOCK option is not specified, the

XP128/XP1024/XP10000/XP12000 has four levels of load balancing for amount of sidefile. Level 0

control is new for load balancing control.

Level 0: Sidefile capacity is less than threshold 1 in the total cache capacity.
MODE 45 = ON: Write I/Os for logical devices are blocked (“Sleep”-“Wait” logic) by the threshold

(500 HEX RECSETS) specified by SDM.
MODE 45 = OFF: Write I/Os are not blocked.

Level 1: Sidefile capacity is over threshold 1 - threshold 2 of the total cache capacity.
MODE 97: “Wait” timer control. Same as level 1 in current load balancing control.

Level 2: Sidefile capacity is over threshold 2 - threshold 3 of the total cache capacity.
MODE 98: “SCP” reporting suppression option. Same as level 2 in current load balancing control.

Level 3: Sidefile capacity exceeds threshold 3 of the total cache capacity. Sidefile puncture occurs.

Same as level 3 in current load balancing control.

Variable sidefile threshold. Two new system options are assigned as variable sidefile threshold as follows.

These options are effective whether Mode 61 = ON or OFF.

MODE 85, 86
• Combination 1: MODE 85,86 = ON,OFF – Threshold 1/2/3=30/40/50%
• Combination 2: MODE 85,86 = OFF,OFF – Threshold 1/2/3=40/50/60% Default
• Combination 3: MODE 85,86 = OFF,ON – Threshold 1/2/3=50/60/70%

Advertising