Considering the m-vol fence level setting, Table 22 fence level setting on a truecopy m-vol, 22 fence level setting on a truecopy m-vol – HP StorageWorks XP Remote Web Console Software User Manual

Page 134: Considering the m-vol fence level, Setting

Advertising
background image

134 TrueCopy for the XP128/XP1024/XP10000/XP12000

• RCU options: Incident of RCU, PPRC Support, Service SIM of Remote Copy, and FREEZE Option (see

Registering an RCU (Add RCU)

” on page 81).

• TC390A offloading timer asynchronous option (see ”

Asynchronous Copy Option

” on page 102)

and TC390A copy pending timeout group option (see

Adding Consistency Groups (Add CT

Group)

” on page 99). The copy pending timeout group option can be used to limit the time

duration during which updates may be lost.

• TC390A Error Level pair option and M-VOL Fence Level pair option for TC390 Synchronous pairs

(see ”

Creating TrueCopy Volume Pairs (Add Pair)

” on page 115).

4.

Establish file and database recovery procedures. These procedures should already be established for

recovering volumes that are inaccessible due to control unit failure.

5.

Install and configure error reporting communications (ERC) between the main and remote sites. ERC is

essential if you use the M-VOL fence level setting of R-VOL Status or Never for any TC390 volume pairs.

6.

Configure the primary host system to use the IEA494I message as a trigger for automation rather than

the IEA491E message. The IEA491E message is reported to only one host, whereas the IEA494I

message is reported to all attached MVS hosts each time the M-VOL pair status changes. For more

information on the IEA494I and IEA491E system console messages, see

IEA494I and IEA491E

Console Messages

” on page 164.

Considering the M-VOL Fence Level Setting

The M-VOL fence level setting (see

Creating TrueCopy Volume Pairs (Add Pair)

” on page 115) for each

TC390 Synchronous volume pair determines whether the M-VOL will be fenced when TC390 remote copy

operations fail. The following table summarizes the effect of the fence level setting on a TC390

Synchronous M-VOL.

NOTE:

The M-VOL fence level setting does not apply to TC390A pairs. The TC390A M-VOL is never

fenced due to suspension of the pair.

R-VOL Data (CRIT=Y(ALL)). When this fence level setting is selected, the M-VOL will be fenced if an update

copy operation fails. This M-VOL fence level setting ensures that the R-VOL remains identical to the M-VOL

after the TC390 volume pair is synchronized, but makes the M-VOL inaccessible to applications for

updates whenever TC390 remote copy operations fail. This setting should be considered for the most

critical volumes for disaster recovery. This setting will reduce the amount of time required to analyze the

currency of the R-VOL during disaster recovery efforts. This setting is also designed for applications that

can continue to operate with another device pair (for example, IMS logger dual write log files).
R-VOL Status (CRIT=Y(PATHS)). When this fence level is selected, the M-VOL is fenced only if the MCU is

not able to change the R-VOL pair status to suspended. If the MCU successfully changes the R-VOL pair

status to suspended, subsequent write I/O operations to the M-VOL will be accepted and the MCU will

keep track of updates to the M-VOL. This allows the volume pair to be resumed quickly using the resync

Table 22

Fence level setting on a TrueCopy M-VOL

Type of Failure

Fence Level Setting
R-VOL Data

(CRIT=Y(ALL))

R-VOL Status

(CRIT=Y(PATHS))

Never

(CRIT=NO)

The update copy operation
failed and the MCU was able
to change the status of the
R-VOL to

suspended

.

Write I/O operations

to the M-VOL will be:

REJECTED Accepted

Accepted

The update copy operation
failed and the MCU was
NOT able to change the
status of the R-VOL to

suspended

.

Write I/O operations

to the M-VOL will be:

REJECTED REJECTED

Accepted