Table 28 troubleshooting suspended truecopy pairs, 28 troubleshooting suspended truecopy pairs, Table 28 – HP StorageWorks XP Remote Web Console Software User Manual

Page 143

Advertising
background image

TrueCopy for z/OS user guide 143

Invalid Port

The specified port is not

configured as an RCP or initiator

port, or this path already exists.

For serial, verify that the correct MCU port is

configured as an RCP and that the correct RCU port is

configured as an LCP.
For Fibre Channel interface, verify that the Fibre

Channel topology settings of the MCU and RCU ports

are correct.
Verify that you entered the correct RCU S/N and SSID

and path parameters (Fibre: MCU port, RCU port, CU

number and Controller ID. Serial: port, link address

and logical address).
Delete the failed path. You may need to change the

minimum paths setting or delete the RCU to delete the

path. Then add the path/RCU using Add Path or Add

RCU.

RCU Port Number

Mismatch

The specified port in the RCU is

physically disconnected from the

MCU.

Verify that you entered the correct RCU port number.

Correct the port number if necessary.
Verify that the MCU and RCU are physically

connected.
For Fibre Channel interface, verify that the Fibre

Channel topology settings of the MCU and RCU ports

are correct.

RCU Port Type

Mismatch

The specified port in the RCU is

not configured as an RCU Target

port.

Verify that the port in the RCU configured as an RCU

Target port. Configure the port as an RCU Target port

if necessary.

Communication

failed.

The MCU connects to the RCU

successfully, but logical

communication time out occurred.

Verify that the RCU port and remote copy connection

hardware (cables and switches) are properly

configured and functioning.

Port Number

Mismatch

The specified port number is not

correct, or the cable is not

connected to the specified port.

Delete the error path.
Verify that you entered the correct port number.
Verify that the cable is connected.

Fibre Remote Copy is

not Supported

The RCU microcode does not

support fibre remote copy.

Install the microcode that supports fibre remote copy

at the RCU.

Communication Error Communication between the

MCU and RCU through the fibre

path timed out.

Delete the failed path.

<blank>

This path was not established.

Delete the failed path. You may need to change the

minimum paths setting or delete the RCU to delete the

path. Then add the path/RCU using Add Path or Add

RCU.

Table 28

Troubleshooting suspended TrueCopy pairs

Suspend Type Applies to Description

Corrective Action

M-VOL by

Operator

M-VOL

The user suspended the pair from the

MCU using the M-VOL Failure option.

The R-VOL suspend type is by MCU.

Resume the pair from the MCU.

R-VOL by

Operator

M-VOL,

R-VOL

The user suspended the pair from the

MCU or RCU using the R-VOL option.

Resume the pair from the MCU.

Table 27

Troubleshooting RCU path status problems (continued)

Path Status

Description

Corrective Action

Advertising