45 mcu/rcu list with the rcu operation command – HP StorageWorks XP Remote Web Console Software User Manual

Page 83

Advertising
background image

TrueCopy for z/OS user guide

83

3.

From the CU number tree on the RCU Operations window, select the correct CU image. For this step,

the list can be blank. You must register RCUs to each CU image separately.

4.

From the MCU/RCU list on the RCU Operations window, right-click to display the pop-up menu. For

registering RCU operation, the RCU does not have to be selected on the list.

5.

From the pop-up menu, click RCU Operation and then click Add RCU (see

Figure 45

). The Add RCU

window is displayed.

Figure 45

MCU/RCU list with the RCU Operation command

6.

From the Add RCU window, enter the S/N of the RCU and the Controller ID, CU number, and SSID(s)

for the CU image. You can enter the Controller ID for Fibre port type. The MCU verifies the S/N when

the paths are established, and verifies the SSIDs when the volume pairs are created. If needed, add

and delete SSIDs later using the Add SSID window (see ”

Adding and Deleting SSIDs for an RCU (Add

SSID and Delete SSID)

” on page 94).

7.

Select the MCU Port and the RCU Port. The MCU will not establish less than the minimum number of

paths as specified on the RCU Option window. If needed, add and delete paths later using the Add

Path window (see

Adding and Deleting Logical Paths for an RCU (Add Path and Delete Path)

” on

page 91).

8.

Click Option to open the RCU Option window. To cancel the settings you made on the Add RCU

window, click Cancel.

9.

From the RCU Option window, enter or select the settings for adding RCU parameters. For multiplatform

XP128/XP1024/XP10000/XP12000 configurations with both TC390 and CA paths, set the

Maximum Initial Copy Activity to 4 Volumes.

10.

From the RCU Option window, click the Set even if you made no changes. To cancel the settings, click

Cancel. The list changes to the RCU Settings Parameter list.

11.

The new RCU is displayed in the RCU Settings Parameter list. To check the path status for this RCU,

select the RCU, right-click to display the pop-up menu, and then click RCU Status. For detailed

information on the path status, refer to

Table 27

on page 143.

NOTE:

The options can be modified and/or canceled after you have set them. See ”

Modifying

Parameters and Omitting Selected Settings

” on page 95.