P/das support, Restrictions – HP StorageWorks XP Remote Web Console Software User Manual

Page 42

Advertising
background image

42

TrueCopy for the XP128/XP1024/XP10000/XP12000

NOTE:

For Fibre Channel interface, do not use the CESTPATH and CDELPATH commands at the

same time as the SCSI path definition function of LUN Management. The Fibre Channel interface

ports need to be configured as initiator ports or RCU target ports before the CESTPATH and

CDELPATH commands are issued.

CAUTION:

Before issuing the CESTPATH command, verify that the relevant paths are offline from

the host(s) (for example, configure the Chipid offline, deactivate the LPAR, or block the port in the

ESCD). If any active logical paths still exist, the add path operation will fail because the port mode

(LCP/RCP) cannot be changed.

You cannot use the PPRC commands to:
Change the RCU options. The current default values are: minimum paths = 1, max. initial copy activity

= 4, SCP delay time = 120 seconds, incident of RCU = to any host, PPRC support = yes, remote copy

service SIM = not report, RIO MIH Time = 15 seconds. The TC390 software must be used to change

these options.
Change the TC390 async options. The current default values are: sidefile threshold = 50%, offloading

timer = 5 minutes. The TC390 software must be used to change these options.
Configure TC390A consistency groups. Because each TC390A pair must belong to one group, the

TC390 software must be used to add and configure the groups (timer type, copy pending timeout, RCU

ready timeout) before you can add any TC390A pairs. After the asynchronous options, groups, and

group options are configured, the PPRC commands can be used to control/monitor TC390A pairs.
Change the initial copy priority. CFW data option, or DFW to R-VOL option. If CESTPAIR is used to

establish a TC390 pair, the following options will be used: initial copy priority = 0, CFW data = copy

to R-VOL, and DFW to R-VOL = not required. The TC390 software must be used to change these

options.

NOTE:

By using Remote Copy Function Switch, you can set the following option with PPRC

command: CFW data = only M-VOL. If you want to use this function, please contact your HP

account support representative.

NOTE:

The DFW to R-VOL setting does not affect the I/O performance of the M-VOLs. If one side of

cache is closed due to an RCU failure, the TC390 copy operation still uses DFW. The only difference

between not required and required is that new pairs cannot be established with the DFW-to-R-VOL

required option when one side of RCU cache is closed (the add pair operation fails).

P/DAS Support

TC390 Synchronous supports the IBM P/DAS host software function. You can use P/DAS to relocate or

migrate data by redirecting all application I/Os from the M-VOL of a TC390 pair to the R-VOL without

interrupting access to the data.TC390A does not support P/DAS SWAP.

Restrictions

P/DAS does not support CFW operations. You must stop CFW applications before performing P/DAS

operations on TC390 volumes.

P/DAS through channel extenders is not supported.

P/DAS swap option #2 (switch pair and swap) is supported for P/DAS between the

XP128/XP1024/XP10000/XP12000 and other XP disk arrays.

Contact your HP account support representative for the latest information on P/DAS support.

Advertising