Error reporting, Figure 74 scripting error code format, Table 60 error messages – HP StorageWorks XP Remote Web Console Software User Manual

Page 195: Table 61 truecopy scripting error codes, 74 scripting error code format, 60 error messages, 61 truecopy scripting error codes

Advertising
background image

TrueCopy for z/OS user guide 195

Error Reporting

The TC390 scripting error codes are slightly different from the general TC390 error codes. The following

figure shows the format of the scripting error codes. The following table describes the TC390 scripting error

messages.

Table 61

on page 196 lists the TC390 scripting error codes. The message ID is the four-digit

number displayed on the error message. The internal code is the four-digit number displayed in the fifth

column of the error trace file (refer to

Script Operations Window

” on page 72). For additional TC390

troubleshooting information, refer to

Troubleshooting

” on page 141.

Figure 74

Scripting error code format

Table 60

Error messages

Error Message

Conditions to Verify

Corrective Action

Syntax error

The syntax validity of the script is checked

at the start of execution. An error message

will be displayed if failed.

Use the scripting error code to determine

which line contains the syntax error (see

Table 61

on page 196) and fix the syntax

error.

Parameter error

The parameter validity of the script is

checked on executing each instruction. An

error message will be displayed if failed.

Use the scripting error code to determine

which line contains the parameter error

(see

Table 61

on page 196) and fix the

parameter error.

Rejection

The result of the execution is checked on

each target device. If failed, the last error

status is displayed and error flag is set in

the reserved variable _Result. Also script

continues to be executed.

If you want to terminate the script or

display a message of error occurrence and

indication following steps, check that

_Result is not 0 in script.

Skip if not executable

The condition of each target device is

checked to be executable status. For

example, the M-VOL status must be simplex

to create a pair. If failed, error flag is set in

the reserved variable _Result. Also script

continues to be executed.

If you want to terminate the script or

display a message of error occurrence and

indication following steps, check that

_Result is not 0 in script.

Table 61

TrueCopy scripting error codes

Message

ID

Internal

Code

Error Message

Error Description

2338

--

Normal End.

The script execution has completed successfully.

2339

1102

Cannot open a file by ‘Memo’

command.

The ‘Memo’ command cannot start the Write

application. The Write.exe file may be absent from

the Windows® directory.

Advertising