Analyzing the currency of truecopy, Synchronous r-vols, Analyzing the – HP StorageWorks XP Remote Web Console Software User Manual

Page 137: Consistency of truecopy asynchronous r-vols

Advertising
background image

TrueCopy for z/OS user guide 137

5.

If necessary, use ICKDSF REFORMAT to change the labels (VOLSERs) of the R-VOLs.

6.

Verify that all required file recovery procedures have been completed before varying the R-VOLs online.

If an IPL of the remote host system is not required, bring the R-VOLs online. If an IPL is required:
a. Clear the remote copy SIMs from the RCUs before OS IPL. Connect to each RCU and click Clear

SIM in the Other Operations window (see ”

Other Operations

” on page 107). Please note that only

an HP CE or ASE should remove SIMs.

b. Perform IPL of the remote host system.
c. Wait until the IPL is complete, and then vary the R-VOLs online (if they did not come online

automatically).

7.

At this point you may start critical applications at the remote site with the previous R-VOLs taking the

place of their M-VOLs.

Analyzing the Currency of TrueCopy Synchronous R-VOLs

The following table shows how to determine the currency of a TC390 Synchronous R-VOL based on its pair

status and M-VOL fence level setting. For TC390 Synchronous pairs with an M-VOL fence level setting of

Never, further analysis will be required to determine the currency of these R-VOLs. The currency of these

R-VOLs can be determined by using the sense information transferred through ERC or by comparing the

contents of the R-VOL with other files that are confirmed to be current (for example, DB2 log files). These

R-VOLs should be recovered using the files that are confirmed to be current.

Analyzing the Consistency of TrueCopy Asynchronous R-VOLs

The following table shows how to determine the consistency of a TC390A R-VOL based on its pair status

and consistency status. For TC390A R-VOLs with a consistency status of Volume, the volume is not

consistent with other volumes in the same group and further analysis will be required to determine the

currency of each of these R-VOLs. To determine the currency of these R-VOLs, use the sense information

Table 23

Analyzing the currency of TrueCopy Synchronous R-VOLs

Status of R-VOL

Fence

Level

Currency of R-VOL

Simplex

Data

Status

Never

Inconsistent. This R-VOL does not belong to a TC390 volume pair.
Even if you established a TC390 pair for this volume, you must regard this

volume as inconsistent.

Pending Duplex

Data

Status

Never

Inconsistent. This R-VOL is not synchronized because not all cylinders have

been copied from the M-VOL yet. This R-VOL must be initialized (or copied

from the M-VOL at a later time).

Duplex

Data

Status

Current. This R-VOL is synchronized with its M-VOL.

Never

Needs to be analyzed. This R-VOL requires further analysis to determine its

level of currency.

Suspended -

initial copy failed

Data

Status

Never

Inconsistent. This R-VOL is not synchronized because not all cylinders have

been copied from the M-VOL yet. This R-VOL must be initialized (or copied

from the M-VOL at a later time).

Suspended -

R-VOL by operator

Data

Status

Never

Suspect. This R-VOL is not synchronized with its M-VOL if any write I/Os

were issued to the M-VOL after the pair was suspended. This pair should be

restarted using the Entire initial copy option, but the No Copy option can be

used if you are sure no data on the M-VOL changed.

Suspended -

all other types

Data

Current. This R-VOL is synchronized with its M-VOL.

Status

Never

Suspect. This R-VOL is not synchronized with its M-VOL if any write I/Os

were issued to the M-VOL after the pair was suspended. Restore the

consistency of this R-VOL and update it, if required. The system time stamp

information transferred through ERC or the time of suspension indicated on

the Pair Status window will help to determine the last time this R-VOL was

updated.

Advertising