Configuring AastraLink Pro 160 System and Network Parameters

You may want to configure the Push Button Trigger feature and the Relay feature
to operate with the same external device. For example, suppose you want the
Operator to monitor and control a locked entrance door. In this scenario, you
could connect the entrance doorbell to the Push Button Trigger, and the locked
entrance door to the Relay I/O port. When the doorbell is pressed, the Aastralink
sends a message to the Operator IP phone that someone is requesting entrance into
the building. The Operator can then unlock the door by pressing the Relay softkey
on the IP phone.

Use the following procedure to configure the Trigger or Relay features.

AastraLink Web UI

Step

Action

1

Select Configuration->System->Relay/Push Button.

2

In the “Relay Delay (seconds)” field, specify a delay time for the relay. Valid range is 1 to 99
seconds. Default is 5.