WARNING

Improper installation of the furnace can result in personal

injury or death. Combustion and flue products must

never be allowed to enter the return air system or air in

the living space. Use sheet metal screws and joint tape

to seal return air system to furnace.

In platform installations with furnace return, the furnace

should be sealed airtight to the return air plenum. A

door must never be used as a portion of the return air

duct system. The base must provide a stable support

and an airtight seal to the furnace. Allow absolutely no

sagging, cracks, gaps, etc.

For no reason should return and supply air duct systems

ever be connected to or from other heating devices such

as a fireplace or stove, etc. Fire, explosion, carbon

monoxide poisoning, personal injury and/or property

damage could result.

Return Air Guidlines
Return air can be brought in through the bottom or either

side of the furnace installed in an upflow application. If the

furnace is installed on a platform with bottom return, make

an airtight seal between the bottom of the furnace and the

platform to ensure that the furnace operates properly and

safely. The furnace is equipped with a removable bottom

panel to facilitate installation.

Markings are provided on both sides of the furnace cabinet

for installations that require side return air. Cut the furnace

cabinet at the maximum dimensions shown on page 2.

Furnace applications which include side return air and a

condensate trap installed on the same side of the cabinet

(trap can be installed remotely within 5 ft.) require either a

return air base or field-fabricated transition to accommodate

an optional IAQ accessory taller than 14.5”. See Figure 11.

Installation Clearances

Top

Bottom (Floor)

Left Side

Right Side

Top/Plenum

1 in. (25 mm)

*Front

0

Back

0

Sides

0†

Vent

0

Floor

0‡

*Front clearance in alcove installation must be 24 in. (610 mm).
Maintain a minimum of 24 in. (610 mm) for front service access.
†Allow proper clearances to accommodate condensate trap.
‡For inst allations on a combustible floor, do not install the furnace
directly on carpeting, tile or other combustible materials other
than wood flooring.

FIGURE 10

Side Return Air

(with transition and filter)

FIGURE 11

Return

Air

Plenum

Transition

20" X 25" X 1"

(508mm X635mm X 25mm)

Air Filter

1−1/2 in.