Air filters must be installed in the system and must be

maintained during construction.

Air filters must be replaced upon construction completion.

The input rate and temperature rise must be set per the

furnace rating plate.

One hundred percent (100%) outdoor air must be provided

for combustion air requirements during construction.

Temporary ducting may supply outdoor air to the furnace.

Do not connect duct directly to the furnace. Size the

temporary duct following the instructions in section for

Combustion, Dilution and Ventilation Air in a confined

space with air from outside.

The furnace heat exchanger, components, duct system,

air filters and evaporator coils must be thoroughly

cleaned following final construction cleanup.

All furnace operating conditions (including ignition, input

rate, temperature rise and venting) must be verified

according to these installation instructions.

General

These instructions are intended as a general guide and do

not supersede local codes in any way. Consult authorities

having jurisdiction before installation.

In addition to the requirements outlined previously, the

following general recommendations must be considered

when installing one of these furnaces:

Place the furnace as close to the center of the air

distribution system as possible. The furnace should also

be located close to the vent termination point.

When the furnace is installed in non-direct vent

applications, do not install the furnace where drafts might

blow directly into it. This could cause improper

combustion and unsafe operation.

When the furnace is installed in non-direct vent

applications, do not block the furnace combustion air

opening with clothing, boxes, doors, etc. Air is needed

for proper combustion and safe unit operation.

When the furnace is installed in an attic or other insulated

space, keep insulation away from the furnace.

When the furnace is installed in an unconditioned space,

consider provisions required to prevent freezing of

condensate drain system.

Note: The Commonwealth of Massachusetts stipulates

these additional requirements:

Gas furnaces shall be installed by a licensed plumber

or fitter only.

The gas cock must be “T handle” type.

When a furnace is installed in an attic, the passageway

to and service area surrounding the equipment shall be

floored.

Combustion, Dilution & Ventilation Air

If this unit is installed as a Non-Direct Vent Furnace,

follow the guidelines in this section.

NOTE: In Non-Direct Vent Installations, combustion air is

taken from indoors and flue gases are discharged outdoors.

In the past, there was no problem in bringing in sufficient

outdoor air for combustion. Infiltration provided all the air

that was needed. In today’s homes, tight construction

practices make it necessary to bring in air from outside for

combustion. Take into account that exhaust fans, appliance

vents, chimneys, and fireplaces force additional air that could

be used for combustion out of the house. Unless outside

Insufficient combustion air can cause headaches,

nausea, dizziness or asphyxiation. It will also cause

excess water in the heat exchanger resulting in rusting

and premature heat exchanger failure. Excessive

exposure to contaminated combustion air will result in

safety and performance related problems. Avoid

exposure to the following substances in the combustion

air supply:

Permanent wave solutions
Chlorinated waxes and cleaners

Chlorine base swimming pool chemicals

Water softening chemicals

De-icing salts or chemicals

Carbon tetrachloride

Halogen type refrigerants

Cleaning solvents (such as perchloroethylene)

Printing inks, paint removers, varnishes, etc.

Hydrochloric acid

Cements and glues

Antistatic fabric softeners for clothes dryers

Masonry acid washing materials

WARNING

These units should not be installed in areas normally

subject to freezing temperatures.

CAUTION

Product Contains Fiberglass Wool.

Disturbing the insulation in this product during

installation, maintenance, or repair will expose you to

fiberglass wool. Breathing this may cause lung cancer.

(Fiberglass wool is known to the State of California to

cause cancer.)

Fiberglass wool may also cause respiratory, skin, and

eye irritation.

To reduce exposure to this substance or for further

information, consult material safety data sheets available

from address shown below, or contact your supervisor.